GYTS kabelining texnik ma'lumotlari
| Mahsulot | Parametrlar | |
| Bo'shashgan naycha | Materiallar | PBT |
| Rang | To'liq rang spektri | |
| To'ldiruvchi | Materiallar | PE |
| Rang | Qora | |
| CSM | Materiallar | Fosfatlovchi po'lat sim |
| Zirhli | Materiallar | Plastik qoplangan alyuminiy tasma |
| Tashqi kurtka | Materiallar | MDPE |
| Rang | Qora | |
| Minimal egilish radiusi | Statik | Kabel diametrining 10 baravari |
| Dinamik | Kabel diametrining 20 baravari | |
| Takrorlanuvchi egilish | Yuk:150N; sikllar soni: 30 Qo'shimcha zaiflashuv yo'q, tola uzilishi yo'q va kabel shikastlanishi yo'q. | |
| Cho'zilish ko'rsatkichi | Qisqa muddatga | 1500N |
| Ezish | Qisqa muddatga | 1000N/100mm |
| Burish | Yuk:150N; sikllar soni: 10; burilish burchagi:±180° Aniq qo'shimcha susayish yo'q, tola uzilishi yo'q va kabel shikastlanishi yo'q. | |
| Ta'sir | Ta'sir energiyasi:450 g×1 m; bolg'a boshining radiusi: 12,5 mm; zarba soni: 5. Qo'shimcha zaiflashuv yo'q, tola uzilishi yo'q va kabel shikastlanishi yo'q. | |
Elyafning o'ziga xos xususiyati:
| Elyaf uslubi | Birlik | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Ahvoli | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Zaiflashuv | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Tarqalish | 1550 nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625 nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| O'tkazish qobiliyati | 850 nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300 nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Nol dispersiya to'lqin uzunligi | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Nol dispersiya qiyaligi | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| PMD maksimal individual tolasi | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| PMD Dizayn Havolasi Qiymati | Ps(nm2*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Elyaf kesish to'lqin uzunligi λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Kabel uzilishi to'lqin uzunligi λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD | 1310 nm | um | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550 nm | um | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Raqamli Diafragma (NA) | ---- | ---- | 0.200± 0.015 | 0,275± 0,015 | 0.200± 0,015 | 0.200± 0,015 | ||
| Qadam (ikki tomonlama o'rtacha qiymat) o'lchov) | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Elyaf uzunligi va nuqtasidagi nosimmetrikliklar | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Farqning orqaga tarqalishi koeffitsient | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Sustlashuvning bir xilligi | dB/km | ≤0.01 | ≤0.01 | |||||
| Yadro diametri | um | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | 50±1.0 | |
| Qoplama diametri | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Qoplamaning aylana shaklida emasligi | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Qoplama diametri | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Qoplama/qoplama konsentrik xato | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Qoplama doirasimon emas | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Yadro/qoplama konsentrikligi xatosi | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Burilish (radius) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Elyaf rangi:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Moviy | To'q sariq | Yashil | Jigarrang | Kulrang | Oq |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Qizil | Qora | Sariq | Binafsha rang | Pushti | Suv |
GYTS kabeli tavsifi
+ GYTS (metall mustahkamlovchi element, bo'shashgan naycha torli va to'ldirilgan, aloqa uchun po'lat-polietilen bilan bog'langan qoplamali tashqi optik tolali kabel).
+ Optik kabelning tuzilishi bitta rejimli yoki ko'p rejimli optik tolani bo'shashgan naychadagi yuqori modulli plastmassadan yasalgan ichki plomba ichiga qoplashdan iborat.
+ Kabel yadrosining markazi metall bilan mustahkamlangan yadrodir. Ba'zi optik tolali kabellar uchun metall bilan mustahkamlangan yadro polietilen (PE) qatlami bilan ham ekstruziya qilinadi.
+ Bo'shashgan naycha (va to'ldirish arqoni) ixcham va dumaloq kabel yadrosini hosil qilish uchun markaziy mustahkamlovchi yadro atrofida o'ralgan va kabel yadrosidagi bo'shliqlar suvni to'suvchi birikmalar bilan to'ldirilgan.
+ Po'lat-plastmassa kompozit lenta uzunlamasına o'raladi va keyin polietilen qoplama bilan ekstruziya qilinadi.
GYTS kabel qurilishi:
GYTS kabelining xususiyatlari:
+ Yaxshi mexanik va harorat ko'rsatkichlari
+ Gidrolizga chidamli yuqori kuchli bo'shashgan naycha
+ Maxsus naycha plomba moddasi tolaning muhim himoyasini ta'minlaydi
+ Maxsus ishlab chiqilgan ixcham tuzilma bo'shashgan naychalarning qisqarishini oldini olishda yaxshi
+ PE qoplamasi kabelni ultrabinafsha nurlanishidan himoya qiladi
Kabelning suv o'tkazmasligini ta'minlash uchun quyidagi choralar ko'riladi:
+ Markaziy mustahkamlik elementi sifatida ishlatiladigan po'lat sim
+ Bo'shashgan naycha plomba aralashmasi
+ 100% kabel yadrosini to'ldirish
+ Yuk tashishdan oldin 100% sinovdan o'tgan.
+ Kabel g'altagi uzunligi: 1 km, 2 km, 3 km, 5 km
GYTA kabeli ilovasi:
+ Tashqi tarqatishga moslashtirilgan.
+ Quvurlarni yotqizish, to'g'ridan-to'g'ri ko'mish, yer osti usuli uchun javob beradi.
+ Shaharlararo va mahalliy tarmoq aloqasi.
Qadoqlash: