GYXTW optik tolali kabel mexanik xususiyatlari:
| GYXTW kabeli | Kabel diametri | Og'irligi |
| Elyaf soni: 2 ta toladan 24 tagacha | 8.0 mm + -0.5 mm | 70 kg/km |
| 7.0 mm + -0.3 mm | 50 kg/km | |
| Harorat oralig'i | -40°C+70°C | |
| Minimal egilish radiusi (mm) | Uzoq muddatli | 10D |
| Minimal egilishRadius (mm) | Qisqa muddatga | 20D |
| Minimal ruxsat etilgan cho'zilish kuchi (N) | Uzoq muddatli | 1200 |
| Minimal ruxsat etilgan cho'zilish kuchi (N) | Qisqa muddatga | 1500 |
| Ishlash harorati | -40°C+70°C | |
| O'rnatish harorati | -20°C+60°C | |
| Saqlash harorati | -40°C+70°C | |
Elyafning o'ziga xos xususiyati:
| Elyaf uslubi | Birlik | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Ahvoli | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Zaiflashuv | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Tarqalish | 1550 nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625 nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| O'tkazish qobiliyati | 850 nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300 nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Nol dispersiya to'lqin uzunligi | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Nol dispersiya qiyaligi | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| PMD maksimal individual tolasi | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| PMD Dizayn Havolasi Qiymati | Ps(nm2*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Elyaf kesish to'lqin uzunligi λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Kabel uzilishi to'lqin uzunligi λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD | 1310 nm | um | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550 nm | um | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Raqamli Diafragma (NA) | ---- | ---- | 0.200± 0.015 | 0,275± 0,015 | 0.200± 0,015 | 0.200± 0,015 | ||
| Qadam (ikki tomonlama o'rtacha qiymat) o'lchov) | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Elyaf uzunligi va nuqtasidagi nosimmetrikliklar | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Farqning orqaga tarqalishi koeffitsient | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Sustlashuvning bir xilligi | dB/km | ≤0.01 | ≤0.01 | |||||
| Yadro diametri | um | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | 50±1.0 | |
| Qoplama diametri | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Qoplamaning aylana shaklida emasligi | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Qoplama diametri | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Qoplama/qoplama konsentrik xato | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Qoplama doirasimon emas | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Yadro/qoplama konsentrikligi xatosi | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Burilish (radius) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Elyaf rangi:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Moviy | To'q sariq | Yashil | Jigarrang | Kulrang | Oq |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Qizil | Qora | Sariq | Binafsha rang | Pushti | Suv |
GYXTW kabeli nima?
•GYXTW optik tolali kabeli, 250 μm tolalar, yuqori modulli plastmassadan yasalgan bo'shashgan naychaga joylashtirilgan.
•Naychalar suv o'tkazmaydigan plomba aralashmasi bilan to'ldirilgan.
•Naycha uzunlamasına PSP qatlami bilan o'ralgan.
•Kabelni ixcham va suv o'tkazmaydigan qilib saqlash uchun PSP va bo'shashgan naycha orasiga suv o'tkazmaydigan material qo'llaniladi.
•Po'lat lentaning ikki tomoniga ikkita parallel po'lat simlar joylashtirilgan.
•Kabel tolani ultrabinafsha nurlaridan himoya qilish uchun qora rangli polietilen (PE) qobiq bilan jihozlangan.
Qurilish:
Xususiyatlari:
•Po'lat simli parallel element, plomba himoya naychali tolali po'lat lenta zirhli.
•Ajoyib mexanik va ekologik ko'rsatkichlar.
•Yilni tuzilish, yengil vazn qulay tarzda o'rnatilishi va oddiygina boshqarilishi mumkin.
•Boshqa optik tolali aloqa variantlari mavjud: bitta rejim (G652D, G657A, G657B) va ko'p rejim (OM1, Om2, Om3, OM4, OM5)
•Elyaf soni: 2fo ~ 12fo
•Diametr opsiyasi: 6.0 mm, 7.0 mm (ishdan tashqari), 8.0 mm
Ilova:
+ Tashqi tarqatishga moslashtirilgan.
+ Havo, quvur yotqizish usuli uchun mos keladi.
+ Shaharlararo va mahalliy tarmoq aloqasi.
Qadoqlash: