SM G657 MPO APC dan LC Fan-out ga 24F Patch kabeli / Mono rejimi 24fibers MTP APC dan LC jabduq kabeli B turi
MPO APC dan LC Fan-out ga 24F Patch kabeli / Mono rejimi 24fibers MTP APC dan LC jabduq kabeliga
Tuzilishi:
Ulagich tomoni A + Asosiy kabel + Ulagich tomoni B
MPO APC / MTP APC 24F SM G657 Mini Kabel 3.0 mm LC/UPC Duplex
24F MPO dan LC / MTP ga LC jabduqlar kabelining qutblanishi
- 24F MPO dan LC jabduq kabeliga / MTP dan LC jabduq kabeliga moslashtirish siz standart A turi, B turi yoki C turi qutblanishidan foydalanayotganingizga bog'liq.
- Eng keng tarqalgan konfiguratsiya B turi (Rollover) bo'lib, u MPO ulagichidagi 1-pinni LC tomonidagi 12-kanalga va 2-pinni 11-kanalga ulaydi.
- Aniq qutblanish xaritasi siz amal qilayotgan strukturaviy kabel standartiga (TIA-568) bog'liq:
+ A turi (to'g'ridan-to'g'ri): 1-tola 1-tolaga, 2-tola 2-tolaga va hokazo ulanadi. Uzatish-qabul qilish (Tx-to-Rx) ni to'g'ri moslashtirishni ta'minlash uchun ulanishning bir uchi standart krossover patch kabelini (A-dan B-ga) talab qiladi.
+ B turi (teskari/aylanuvchi): 1-tola 24-tolaga, 2-tola 23-tolaga va boshqalarga ulanadi. Bu usul to'g'ridan-to'g'ri apparat yamoqlari (masalan, 40G/100G transversiyalari) uchun juda mashhur, chunki u Tx va Rx ni avtomatik ravishda uzluksiz ravishda o'zgartiradi.
+ C turi (Juftlik bilan almashtiriladi): Qo'shni optik tolali juftliklar almashtiriladi (masalan, 1↔2, 3↔4, 5↔6). Bu standart Tx/Rx hizalanishini o'zaro bog'liq yamoq kabellariga ehtiyoj sezmasdan saqlaydi, lekin ehtiyotkorlik bilan sozlangan magistral kabellarni talab qiladi.
24F MPO APC / MTP APC ulagichi
Buyurtma haqida batafsil ma'lumot
- A tomonidagi ulagichi:
MPO/APC 24F,
MTP/APC 24F
- A tomonidagi ulagichi:
Erkak
Ayol
- Kabel: Yagona rejimli G657A1 mikro yuqori zichlikli kabel 3.0 mm
- Elyaf soni: 24fo
- Sice B ulagichi:
LC UPC Dupleks
LC UPC birlik yuklash dupleksi
- Ventilyator diametri: 2.0 mm
- Fanout uzunligi: 30 sm, 50 sm
- Uzunlik: moslashtirilgan
- Polarlik: A turi, B turi, C turi
- Qo'shishdagi yo'qotish: Elite (ULL), Standard.
- Yorliq: moslashtirilgan
- Miqdori: MOQ 1 dona
Ilovalar
+ FTTx (FTTA, FTTB, FTTC, FTTH, FTTO va boshqalar)
+ Ma'lumotlar markazining o'zaro aloqasi
+ WAN/LAN
+ Yuqori tezlikdagi temir yo'l stantsiyasining boshqaruv xonasi
+ Sun'iy intellekt ma'lumotlar markazi
+ Star-link ma'lumotlar markazi
+ Bank ma'lumotlar markazi
Texnik xususiyatlar
| Turi | Yagona rejim | Yagona rejim | Ko'p rejim | |||
| (APC Polsha) | (UPC Polsha) | (Kompyuter polyakchasi) | ||||
| Elyaf soni | 8f, 12f, 16f, 24f, 32f, 48f | 8f, 12f, 16f, 24f, 32f, 48f | 8f, 12f, 16f, 24f, 32f, 48f | |||
| Elyaf turi | G657A1, G657A2 | G657A1, G657A2 | OM1, OM2, OM3, OM4, OM5 va boshqalar. | |||
| Maksimal qo'shish yo'qotishi | Elita | Standart | Elita | Standart | Elita | Standart |
| Ultra past yo'qotish | Ultra past yo'qotish | Kam yo'qotish | ||||
| ≤0,35 dB | ≤0,75 dB | ≤0,35 dB | ≤0,75 dB | ≤0,35 dB | ≤0,60 dB | |
| Qaytish yo'qotishi | ≥60 dB | ≥60 dB | NA | |||
| Chidamlilik | ≥500 marta | ≥500 marta | ≥500 marta | |||
| Ishlash harorati | -40℃~+80℃ | -40℃~+80℃ | -40℃~+80℃ | |||
| To'lqin uzunligini sinash | 1310 nm | 1310 nm | 1310 nm | |||
| Qo'shish-tortish sinovi | 1000 marta<0,5 dB | |||||
| Almashuv | <0,5 dB | |||||
| Cho'zilishga qarshi kuch | 15 kgf | |||||