KCO-SFP+-SR 10Gb/s 850nm ko'p rejimli SFP+ qabul qilgich-uzatgich
Ilovalar
+ 10GBASE-SR/Janubi-g'arbiy& 10G Ethernet
Standart
+ SFP+ SFF-8431 ga mos keladi
+ 802.3ae 10GBASE-SR ga mos keladi.
+ RoHSga mos keladi
Mutlaq maksimal reytinglar
| Parametr | Belgi | Min. | Turi. | Maks. | Birlik |
| Saqlash harorati | Ts | -40 | - | 85 | ºC |
| NisbiyNamlik | RH | 5 | - | 95 | % |
| Quvvat manbai kuchlanishi | VCC | -0.3 | - | 4 | V |
| Signal kirish kuchlanishi |
| Vcc-0.3 | - | Vcc+0.3 | V |
Tavsiya etilgan ish sharoitlari
| Parametr | Belgi | Min. | Turi. | Maks. | Birlik | Eslatma |
| Ishlash harorati | Tish | 0 | - | 70 | ºC | Havo oqimisiz |
| Quvvat manbai kuchlanishi | VCC | 3.14 | 3.3 | 3.47 | V |
|
| Quvvat manbai oqimi | XKM | - |
| 300 | mA |
|
| Ma'lumotlar tezligi | BR |
| 10.3125 |
| Gbit/s |
|
| Uzatish masofasi | TD |
| - | 300 | m |
|
| Bog'langan tola | Ko'prejimli tola | 50/125umMMF | ||||
Optik xususiyatlar
| Parametr | Belgi | Min | Turi | Maks | Birlik | Malumotnoma |
| Uzatuvchi | ||||||
| Chiqish Opt. Pwr | POUT | -6 | -1 | dBm | 1 | |
| Optik to'lqin uzunligi | λ | 840 | 850 | 860 | nm | |
| Optik o'chirish nisbati | ER | 3.0 | dB | |||
| RIN | RIN | -128 | dB/Hz | |||
| Chiqish ko'z niqobi | IEEE 802.3a standartiga mos keladie | |||||
| Qabul qilgich | ||||||
| Retsept bo'yicha sezgirlik | RSENS | -10 | dBm | 2 | ||
| Kirish to'yinganlik quvvati (ortiqcha yuklanish) | Psat | 0,5 | dBm | |||
| To'lqin uzunligi diapazoni | λC | 770 | 850 | 860 | nm | |
| LOS De -Assert | LOSD | -14 | dBm | |||
| LOS Assert | LOSA | -30 | dBm | |||
| LOS gisterezisi | 0,5 | dB | ||||
Izohlar:
- FDA/CDRH va IEC-825-1 qoidalariga muvofiq 1-sinf lazer xavfsizligi.
- PRBS 2 bilan o'lchangan31-1 sinov namunasi, @10.325Gb/s, BER<10-12.
IV. Elektr xususiyatlari
| Parametr | Belgi | Min | Turi | Maks | Birlik | ESLATMA |
| Ta'minot kuchlanishi | Vcc | 3.14 | 3.3 | 3.46 | V | |
| Ta'minot oqimi | ICC | 300 | mA | |||
| Uzatuvchi | ||||||
| Kirish differentsial empedansi | Rin | 100 | Ω | 1 | ||
| Bir martalik ma'lumotlarni kiritish tebranishi | Vin,pp | 180 | 700 | mV | ||
| Uzatish kuchlanishini o'chirish | VD | Vcc–1.3 | Vcc | V | ||
| Uzatish kuchlanishini yoqish | VEN | Vee | Vee+ 0.8 | V | 2 | |
| Tasdiqlash vaqtini o'chirishni uzatish | 10 | us | ||||
| Qabul qilgich | ||||||
| Differentsial ma'lumotlar chiqishi tebranishi | Vout, pp | 300 | 850 | mV | 3 | |
| Ma'lumotlar chiqishining ko'tarilish vaqti | tr | 28 | ps | 4 | ||
| Ma'lumotlar chiqishining pasayish vaqti | tf | 28 | ps | 4 | ||
| LOS xatosi | VLOS xatosi | Vcc–1.3 | VccHOST | V | 5 | |
| LOS Normal | VLOS normasi | Vee | Vee+0.8 | V | 5 | |
| Quvvat manbaini rad etish | PSR | 100 | mVpp | 6 |
Izohlar:
- To'g'ridan-to'g'ri TX ma'lumotlar kirish pinlariga ulangan. Shundan so'ng AC ulangan.
- Yoki ochiq elektron.
- 100 ohmli differentsial tugatishga.
- Bular filtrlanmagan 20-80% qiymatlar
- Signalning yo'qolishi LVTTL. 0-mantiq normal ishlashni bildiradi; 1-mantiq signal aniqlanmaganligini bildiradi.
- Qabul qilgichning sezgirligi tavsiya etilgan quvvat manbai filtrlash tarmog'i orqali qo'llaniladigan belgilangan qiymatgacha 20 Gts dan 1,5 MGts gacha bo'lgan quvvat manbai sinusoidal modulyatsiyasiga mos keladi.
Kontur o'lchamlari
SFF-8432 rev5.0, takomillashtirilgan Pluggable form-faktor spetsifikatsiyasiga mos keladi.