Tarqatish fanout qattiq bufer yopiq optik tolali kabel (GJFJV)
Texnik parametrlar:
| Fanout ichki tolali optik kabel (GJFJV) | Kabel diametri | Og'irligi | |
| 2 yadro | 4,5 mm | 22,00 kg/km | |
| 4 yadro | 4,5 mm | 22,00 kg/km | |
| 6 yadro | 4,5 mm | 23,00 kg/km | |
| 8 yadro | 5,5 mm | 27,00 kg/km | |
| 10 yadro | 5,5 mm | 30,00 kg/km | |
| 12 yadro | 6,0 mm | 35,00 kg/km | |
| Saqlash harorati (℃) | -20+60 | ||
| Minimal egilish radiusi (mm) | Uzoq muddatli | 10D | |
| Minimal egilish radiusi (mm) | Qisqa muddatga | 20D | |
| Minimal ruxsat etilgan kuchlanish kuchi (N) | Uzoq muddatli | 200 | |
| Minimal ruxsat etilgan kuchlanish kuchi (N) | Qisqa muddatga | 600 | |
| Ezilgan yuk (N/100 mm) | Uzoq muddatli | 200 | |
| Ezilgan yuk (N/100 mm) | qisqa muddatga | 1000 | |
Elyafning xarakteristikasi:
| Elyaf uslubi | Birlik | SMG652 | SMG652D | SMG657A | MM50/125 | MM62,5/125 | MMOM3-300 | ||
| holat | nm | 1310/1550 | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| susaytirish | dB/km | ≤0,36/0,23 | ≤0,34/0,22 | ≤.035/0.21 | ≤3,0/1,0 | ≤3,0/1,0 | ≤3,0/1,0 | ||
| Dispersiya | 1550 nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- | ---- | |
| 1625 nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- | ---- | ||
| Tarmoqli kengligi | 850 nm | MHZ.KM | ---- | ---- | ≥400 | ≥160 | |||
| 1300 nm | MHZ.KM | ---- | ---- | ≥800 | ≥500 | ||||
| Nolinchi dispersiya to'lqin uzunligi | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Nolinchi dispersiyali nishab | nm | ≤0,092 | ≤0,091 | ≤0,090 | ---- | ---- | ---- | ||
| PMD maksimal individual tolasi | ≤0,2 | ≤0,2 | ≤0,2 | ---- | ---- | ≤0,11 | |||
| PMD dizayn havolasi qiymati | Ps (nm2*km) | ≤0,12 | ≤0,08 | ≤0,1 | ---- | ---- | ---- | ||
| Elyafni kesish to'lqin uzunligi lc | nm | ≥ 1180≤1330 | ≥1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Kabelning uzilishito'lqin uzunligi lcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD | 1310 nm | um | 9,2±0,4 | 9,2±0,4 | 9,0±0,4 | ---- | ---- | ---- | |
| 1550 nm | um | 10,4±0,8 | 10,4±0,8 | 10,1±0,5 | ---- | ---- | ---- | ||
| RaqamliDiafragma (NA) | ---- | ---- | ---- | 0,200± 0,015 | 0,275±0,015 | 0,200±0,015 | |||
| Qadam(ikki tomonlama ma'nosio'lchov) | dB | ≤0,05 | ≤0,05 | ≤0,05 | ≤0,10 | ≤0,10 | ≤0,10 | ||
| Elyaf ustidagi tartibsizliklaruzunlik va nuqta | dB | ≤0,05 | ≤0,05 | ≤0,05 | ≤0,10 | ≤0,10 | ≤0,10 | ||
| Uzluksizlik | |||||||||
| Farqning orqaga tarqalishikoeffitsienti | dB/km | ≤0,05 | ≤0,03 | ≤0,03 | ≤0,08 | ≤0,10 | ≤0,08 | ||
| Zaiflashning bir xilligi | dB/km | ≤0,01 | ≤0,01 | ≤0,01 | |||||
| Yadro diametri | um | 9 | 9 | 9 | 50±1,0 | 62,5±2,5 | 50±1,0 | ||
| Qoplama diametri | um | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | ||
| Qoplamaning aylana bo'lmaganligi | % | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | ||
| Qoplama diametri | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Qoplama / somonkonsentrik xato | um | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | ||
| Qoplama dumaloq emas | % | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | ||
| Yadro/qoplama konsentrikligi xatosi | um | ≤0,6 | ≤0,6 | ≤0,6 | ≤1,5 | ≤1,5 | ≤1,5 | ||
| Curl (radius) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Kabel konstruksiyalari:
Kabelni kesish:
Ko'p rejimli OM3 8 yadroli Kabel
Yagona rejimli 4 yadroli Kabel
Multimode 50/125 24 yadroli Kabel
Tavsiflar:
•Distribution Fanout Tight Buffer Indoor tolali optik kabeli optik sub kabel sifatida 2 ~ 48 yadroli (yoki undan ko'p) 900 mikron yoki 600 mikron zich bufer tolasidan foydalanadi. Odatda u PVX yoki LSZHdan foydalanishni qoplaydi, shuningdek, PE yoki Nilondan foydalaning.
•Qattiq tampon tolasi mustahkamlik elementi sifatida aramid ip qatlami bilan o'ralgan, so'ngra ko'ylagi sifatida PVX yoki LSZH materiali qatlami bilan to'ldirilgan.
•Distribution Fanout Tight Buffer Indoor Fiber Optik Kabel tashqi ko'ylagi rangi:
Yagona rejim: sariq,
Ko'p rejimli OM1 / OM2: to'q sariq,
Multimode OM3 / OM4: Aqua,
Multimode OM4: binafsha,
Mutimode OM5: Ohak.
Boshqa rang ixtiyoriy.
Ilova:
+ Pigtaillar va yamoq kordonlarida ishlatiladi.
+ Uskunalarni o'zaro bog'lash liniyalari sifatida ishlatiladi va optikada optik ulanishlarda ishlatiladialoqa xonalari, ma'lumotlar markazi va optik tarqatish ramkalari.
+ Ichki kabellarda ishlatiladi, ayniqsa tarqatish kabeli sifatida ishlatiladi.
Xususiyatlari:
•Yaxshi mexanik va ekologik xususiyatlar.
•Olovga chidamli xususiyatlar tegishli standartlar talablariga javob beradi.
•Jekning mexanik xususiyatlari tegishli standartlar talablariga javob beradi.
•Yumshoq, moslashuvchan, yotqizish va ulash oson va katta hajmli ma'lumotlarni uzatish.
•Bozor va mijozlarning turli talablariga javob bering.
Ilova: ko'p tolali pigtail / patch shnurli ichki kabelni chiqarish uchun ishlatiladi
+ Pigtaillar va yamoq kordonlarida ishlatiladi.
+ Uskunalarni o'zaro bog'lash liniyalari sifatida ishlatiladi va optikada optik ulanishlarda ishlatiladi
aloqa xonalari va optik tarqatish ramkalari.
+ Ichki kabellarda ishlatiladi, ayniqsa tarqatish kabeli sifatida ishlatiladi.
Qadoqlash: